Precision Cable Manufacturing: How Each Layer Is Made | JINLIANYU Cable
4 week agoCopper braid screening around the control cores
JINLIANYU KVVP cable incorporates a copper wire braid around the insulated core assembly. Copper conductors, PVC insulation and a black PVC outer sheath form a 450/750 V control-cable construction. The braid is the defining selection feature when an industrial wiring schedule calls for a screened control cable.

Specify the screen as part of the cable construction
The exposed end shows the braid between the insulated conductors and the surrounding sheath. Include this screen type in the purchase specification so it remains distinct from a copper-tape screen or an unscreened cable. Cable termination and screen connection details should follow the electrical design for the connected instruments.
KVVP materials and electrical rating
Read core count and conductor size together
The illustrated KVVP sample is marked 14 × 2.5 mm². This designation identifies fourteen conductors, each with a nominal cross-section of 2.5 mm². For a multi conductor control cable, both values belong on the cable schedule: the number of instrument connections and the conductor size answer different selection questions. The sample sits within the stated 0.5–10 mm² size range.


Industrial instrumentation and distribution circuits
KVVP is used for signal transmission, control and measurement in electrical instruments and distribution equipment at metallurgical, power and petrochemical facilities. Within the JINLIANYU Control Cables range, its braided screen and PVC construction provide the model identity. Review the 450/750 V rating, 70°C working temperature and installation environment against the circuit specification.
From conductor processing to inspection
Workshop and resistance-testing views accompany the cable details. For a multicore control cable order, keep the material specification and conductor size attached to each schedule item. Where inspection documents are needed, identify the required checks and the corresponding cable designation in the enquiry.


Details to include with a KVVP enquiry
List the KVVP designation, conductor count, nominal cross-section and required length for each item. State the total order quantity and any identification or documentation requirements. Include the intended instrument or distribution circuit and the specified screen connection arrangement so the requested configuration can be reviewed accurately.
Separate a woven braid from a foil screen
When reviewing braided shield vs foil shield options, identify how the screening layer is made. A wire braid uses interwoven strands around the core assembly; a foil screen uses a thin metallic layer. The KVVP construction specified here has a copper wire braid.
State the required screen construction and its connection arrangement in the equipment specification. Match the screen to the termination hardware and electrical design, together with the conductor count and section.
Check the marked configuration against the schedule
The photographed sheath reads KVVP, 450/750 V and 14×2.5 mm². Record the model and voltage separately from the conductor count and nominal area. Fourteen cores at 2.5 mm² describe this sample configuration; request the finished outside diameter for the exact item being offered.
Readable sheath designation on the screened fourteen-core sample.
Similar Video Recommendation
If you are interested in the product, contact Bossgoovideo.com for more information
- *To:
- Guangdong Jinlianyu Cable Group Co., Ltd.
- *Message:
-
Submit
Main Product:
Power Cables,
Building Wires,
Control Cables,
Rubber-Sheathed Cables,
New Energy Cables ,
Orange Circular Cable