Health & Medical Easy Use Urine Multi DrugTest kit COT COC KET1
3 year ago
Product Name FOB Fecal Occult Blood Rapid Test Kit
Intended Use The test kit is designed for the qualitative detection of human occult blood in feces according to the principle of gold
immunochromatography assay.Feces detection is a common indicator of digestive tract diseases, and is very important in the diagnosis of digestive tract
diseases. The detection of gastrointestinal bleeding is an effective method to find occult blood and one of the important means
for clinical diagnosis and monitoring of digestive tract hemorrhage disease. It is a cautionary tale for the early screening ofthe colorectal diseases in asymptomatic patients.
PrincipleThe test utilizes antibodies including a anti-human hemoglobin monoclonal antibody on the nitrocellulose membrane with colloidal gold marked Hb as an mark tracer. The reagent is used to detect the Hb in feces according to the principle of double antibody sandwich method and gold immunochromatography assay.
The sample mixing up anti-human hemoglobin monoclonal antibody–marker move along the membrane to the T line, and form the T line when the sample contains Hb, which a positive result. Conversely, it is a negative result.Main Components Basic components: Sample pad, colloidal gold marked pad, nitrocellulose membrane, absorbent paper and PVC board. Colloidal gold marked pad coated with anti-human hemoglobin monoclonal antibody A, nitrocellulose membrane coated with anti-human hemoglobin monoclonal antibody B, control line coated with goat anti-mouse IgG antibody.
Storage and Expiry Store as packaged in the sealed pouch at 4-30°C, avoid hot and sunshine, dry place, valid for 24 months. DO NOT FREEZE. Some protective measures should be taken in hot summer and cold winter to avoid high temperature or freeze-thaw.
2. Limited by the detection method, the experimental personnel should pay more attention to the negative results. If fecal
occult blood is still suspected, the sample should be collected later and carry the detection with other methods.
3. Negative result may occur when detecting samples with concentration exceed 2000μg /mL, indicate that the sample should be diluted (50~100 times) before tested again.
















|
|
|
|
|
Similar Video Recommendation
You May Also Like
If you are interested in the product, contact Bossgoovideo.com for more information
- *To:
- Changchun ZYF science and technology CO.,LTD
- *Message:
-
Submit
Main Product:
Rapid Test Kit ,
Urinalysis Reagent Strip,
Biochemistry Analyzer,
Hematology Analyzer,
POCT Analyzer,
Medical Consumables
You May Also Like